F5
Inverter
|
|
KEB COMBIVERT
With the adage "as much as necessary", provides
graduated features creating an optimum solution for
each application. Universal functionality, identical
handling, and common tools serve to reduce the work
which is necessary for installation, start-up and
service regardless which type of unit is ultimately
used.
|
KEB COMBIVERT
|
|
|
|
KEB COMBIVERT
|
|
KEB COMBIVERT F5 BASIC - The new frequency inverter class of sensorless vector inverter for simple to demanding applications in any industry...Sensorless vector inverter 0.5 … 15 hp |
•
|
connection 1/3 phase 230 V and 3 phase 460 V, can also be supplied with DC |
•
|
optimized motor performanceKEB-SMM (sensorless motor management) |
• |
17 pluggable control terminals, PNP-logic |
•
|
analog input 0…10 V, + 10 V, 0 /4 …20 mA (with housing D) |
•
|
programmable analog output 0 …10 V |
•
|
5 programmable digital inputs |
•
|
2 programmable relay outputs |
•
|
4 programmable software inputs/outputs |
•
|
8 programmable parameter sets with functions like S-curve, ramp stop, Power-off-function, DC-braking, PID process controller, |
|
electronic motor protection, brake control, internal timer, counter input among other things |
•
|
output frequencies up to 400 Hz (1600 Hz), output voltage stabilization, adjustable switching frequencies up to 16 kHz |
•
|
index positioning function |
•
|
high speed scan of the control terminals and the serial interface every 2 ms |
•
|
+ / - DC connection, internal braking chopper (option starting from housing size H), motor thermal sensor connection, hardware current limits |
•
|
high voltage isolated operator connection, serial interfaces Profibus, Interbus, CAN, Sercos, Device Net, KEB-HSP 5 / DIN 66019-II |
KEB COMBIVERT F5 BASIC / |
size
|
phases
|
PN
|
IN
|
Imax
|
fnom/fmax
|
w x h x d * |
_ |
-
|
[hp]
|
[A]
|
[A]
|
[kHz]
|
[inch] |
05
|
1 |
0.5
|
2.0
|
4.1
|
8 |
3 x 7.25 x 5.75
|
07
|
1 |
1
|
4.0
|
7.2
|
8 |
3 x 7.25 x 5.75
|
09
|
1 / 3 |
2
|
6.8
|
12.6
|
16 |
3.5 x 8.75 x 6.25
|
10
|
1 / 3 |
3
|
9.6
|
18
|
8 |
3.5 x 8.75 x 6.25
|
12 |
3 |
5
|
15.2
|
30 |
8 |
3.5 x 10 x 7.25 |
13 |
3 |
7.5 |
28 |
36 |
8 |
5 x 11.5 x 8 |
14 |
3 |
10 |
33 |
50 |
4** |
5 x 11.5 x 8 |
15 |
3 |
15 |
42 |
72 |
4** |
6.75 x 13.5 x 10 |
16 |
3 |
20 |
54 |
99 |
16 |
11.75 x 13.5 x 10 |
*dimensions without submounted
braking resistor and operator
/ ** other units with higher carrier
frequencies are available
KEB COMBIVERT F5 BASIC / |
size
|
phases
|
PN
|
IN
|
Imax
|
fnom/fmax
|
w
x h x d * |
_ |
-
|
[hp]
|
[A]
|
[A]
|
[kHz]
|
[inch] |
05
|
3 |
0.5
|
1.0
|
2.3
|
16 |
3.5 x 8.75 x 6.25
|
07
|
3 |
1
|
1.8
|
4.7
|
16 |
3.5 x 8.75 x 6.25
|
09
|
3 |
2
|
3.4
|
7.4
|
8 |
3.5 x 8.75 x 6.25
|
10
|
3 |
3
|
4.8
|
10
|
8 |
3.5 x 8.75 x 6.25
|
12 |
3 |
5
|
7.6
|
17 |
4** |
3.5 x
8.75 x 6.25 |
13 |
3 |
7,5 |
11 |
22 |
4** |
3.5 x
10 x 7.25 |
14 |
3 |
10 |
14 |
30 |
8 |
3.5 x
10x 7.25 |
15 |
3 |
15 |
21 |
36 |
4** |
5 x
11.5 x 8 |
16 |
3 |
20 |
27 |
50 |
8 |
5 x
11.5 x 8 |
*dimensions without
submounted braking resistor and operator / ** other units with higher
carrier frequencies are available
KEB COMBIVERT
F5 GENERAL more than just a frequency inverter! Top technique
for controlling motor/drive systems in the range of 0.5… 125 hp
universal features provide the basis for a wide range of application
solutions |
•
|
wide power range for 230V and
460V connection |
•
|
optional AC- or DC-connection |
• |
optimal performance at the motor shaft in different applications with
KEB-SMM (sensorless motor management) |
•
|
29 pluggable control terminals |
•
|
2 analog inputs 0…10 V, +
10 V, 0 / 4 … 20 mA |
•
|
2 programmable analog outputs |
•
|
8 programmable digital inputs (NPN
or PNP) |
•
|
programmable outputs: 2 x
relay, 2 x transistor |
•
|
4 programmable software
inputs/outputs |
• |
8 programmable parameter sets
with S-curves, ramp stop, Power-off-function, DC-braking, PID process
controller, electronic motor protection |
|
brake control, internal timer,
counter input, output frequencies up to 1600 Hz, output voltage
stabilization, switching frequencies up to 16 kHz |
•
|
output phase monitoring, just
to mention a few |
• |
sampling time of the control
terminals 1 ms |
•
|
DC bus circuit connection,
internal braking transistor (standard up to housing size R) motor
thermal sensor connection, hardwaer current limit |
•
|
index positioning function -
open loop or with built-in high speed counter |
•
|
optinal: protection against
unintended start through internal disconnection of the driver section (
cat. 3). |
•
|
high voltage isolated operator
connection, and serial interfaces for Profibus, Interbus, CAN, Sercos,
Device Net, KEB-HSP 5 / DIN 66019-II |
KEB COMBIVERT F5 COMPACT / |
size
|
phases
|
PN
|
IN
|
Imax
|
fnom/fmax
|
w
x h x d * |
_ |
-
|
[hp]
|
[A]
|
[A]
|
[kHz]
|
[inch] |
05 |
1 / 3 |
0.5 |
2.3 |
4.1 |
16 |
3.5 x 8.75 x 6.25
|
07 |
1 / 3 |
1 |
4.0 |
7.2 |
16 |
3.5 x 8.75 x 6.25
|
09 |
1 /
3 |
2 |
7.0 |
13 |
16 |
3.5 x 8.75 x 6.25
|
10 |
1 /
3 |
3 |
10 |
18 |
8 |
3.5 x 8.75 x 6.25
|
12 |
3 |
5 |
15.2 |
30 |
8 |
3.5 x
10 x 7.25 |
13 |
3 |
7.5 |
22 |
36 |
4** |
5 x
11.5 x 8 |
14 |
3 |
10 |
28 |
50 |
4** |
5 x
11.5 x 8 |
15 |
3 |
15 |
42 |
72 |
16 |
6.75
x 13.5 x 10 |
16 |
3 |
20 |
54 |
99 |
16 |
11.75
x 13.5 x 10 |
17 |
3 |
25 |
68 |
126 |
8 |
13.5
x 20.5 x 14 |
18 |
3 |
30 |
80 |
150 |
8 |
13.5
x 20.5 x 14 |
19 |
3 |
40 |
104 |
172 |
8 |
13.5
x 20.5 x 14 |
20 |
3 |
50 |
130 |
225 |
8 |
13.5
x 20.5 x 14 |
21 |
3 |
60 |
154 |
270 |
8 |
13.5
x 20.5 x 14 |
*dimensions without submounted
braking resistor and operator / other carrier
frequencies are available
KEB COMBIVERT F5 COMPACT / 460 |
size
|
phases
|
PN
|
IN
|
Imax
|
fnom/fmax
|
w
x h x d * |
_ |
-
|
[hp]
|
[A]
|
[A]
|
[kHz]
|
[inch] |
05 |
3 |
0.5 |
1.3 |
2.3 |
16 |
3.5 x 8.75 x 6.25
|
07 |
3 |
1 |
2.6 |
4.7 |
16 |
3.5 x 8.75 x 6.25
|
09 |
3 |
2 |
4.1 |
7.4 |
8/16 |
3.5 x 8.75 x 6.25
|
10 |
3 |
3 |
5.8 |
10 |
8/16 |
3.5 x 8.75 x 6.25
|
12 |
3 |
5 |
9.5 |
17 |
4 |
3.5 x
8.75 x 6.25 |
13 |
3 |
7.5 |
11 |
22 |
4/16 |
3.5 x
10 x 7.25 |
14 |
3 |
10 |
17 |
30 |
2/4 |
3.5 x
10 x 7.25 |
15 |
3 |
15 |
21 |
36 |
4/16 |
5 x
11.5 x 8 |
16 |
3 |
20 |
27 |
50 |
2/4 |
5 x
11.5 x 8 |
17 |
3 |
25 |
34 |
63 |
4/16 |
6.75
x 13.5 x 10 |
18 |
3 |
30 |
40 |
75 |
4/16 |
6.75
x 13.5 x 10 |
19 |
3 |
40 |
52 |
90 |
4/16 |
11.75
x 13.5 x 10 |
20 |
3 |
50 |
65 |
112 |
8/16 |
13.5
x 20.5 x 14 |
21 |
3 |
60 |
77 |
135 |
4/16 |
13.5
x 20.5 x 14 |
22 |
3 |
75 |
96 |
172 |
4/16 |
13.5
x 20.5 x 14 |
23 |
3 |
100 |
136 |
225 |
2/12 |
13.5
x 20.5 x 14 |
24 |
3 |
125 |
172 |
270 |
2/8 |
13.5
x 20.5 x 14 |
*dimensions without submounted
braking resistor and operator / other carrier
frequencies are available
|
|
|
|